Compressed air consumption of a double-acting cylinder

Cylinder chamber volumes are filled with compressed air during each stroke. The normal-liter equivalent depends on the absolute-to-reference pressure ratio and differs from the internal compressed volume.

Deutsche Originalfassung · Español

Calculate your result

Use the corresponding calculator with values for your product or project. This guide cannot verify local technical rules.

Open German calculator →

Step-by-step guidance

1. Verify inputs and reference conditions

Identify the bore, rod diameter and stroke of a double-acting cylinder, counting both directions in each cycle. Confirm the entered units and document assumptions before applying this result to actual equipment.

2. Apply the formula and check units

Convert chamber volume into normal liters using absolute pressure and multiply by complete cycles per minute. Confirm the entered units and document assumptions before applying this result to actual equipment.

3. Review practical limitations

Account for leaks, pipe filling, air treatment and peak demand when specifying a compressor or accumulator. Confirm the entered units and document assumptions before applying this result to actual equipment.

Formula

Cycle volume = π/4 × (2 bore² − rod²) × stroke. Normal liters = compressed volume × (1 + gauge pressure / 1.01325 bar).

Worked example

For a 40/16 mm cylinder, 200 mm stroke, 6 bar gauge and 10 full cycles per minute, ideal demand is about 32 normal liters per minute.

Common mistakes

  • Counting only one cylinder chamber
  • Confusing gauge and absolute pressure
  • Equating normal liters with compressed volume

Frequently asked questions

What counts as a complete cycle?

One extension and one retraction are one complete cycle in this model.

Is the result the minimum compressor size?

No. It excludes other consumers, leaks and the necessary pressure and flow reserve.

Example values are planning assumptions, not binding product specifications. Check local rules, supplier information and professional guidance. Electrical examples do not establish a safe installation or protection.