Efficiency: useful output, input power and losses

Efficiency expresses how much of the energy entering a defined system boundary becomes the intended useful output. The remaining part may leave as heat, sound or other less useful forms. A device does not necessarily have the same efficiency across all loads and temperatures.

Deutsche Originalfassung · Español

Calculate your result

Use the corresponding calculator with values for your product or project. This guide cannot verify local technical rules.

Open German calculator →

Step-by-step guidance

1. Define the system boundary

Decide whether the input describes only a motor or also its control and auxiliary equipment. Mixing different system boundaries makes efficiency comparisons misleading even when the percentage values look similar.

2. Apply efficiency as a fraction

Divide the percentage by 100 before multiplying it by input power. Subtract useful output power from input power to estimate the remaining loss under the assumed operating condition.

3. Turn power losses into energy losses

Multiply the constant loss power by operating hours and divide by 1,000 to obtain kWh. Real equipment often varies its load, so a measured time series is better for annual totals.

Formula

Useful power (W) = input power × efficiency/100; loss energy (kWh) = (input − useful power) × operating hours / 1,000.

Worked example

At 200 W input and 85% efficiency, useful power is 170 W while 30 W is lost. Ten operating hours produce an estimated 0.30 kWh of losses.

Common mistakes

  • Multiplying by 85 instead of 0.85
  • Comparing input power defined at different boundaries
  • Confusing watts of loss with kilowatt-hours of lost energy

Frequently asked questions

Can conversion efficiency exceed 100% here?

Not under this direct energy-balance definition; heat-pump performance is described differently.

Is efficiency constant at partial load?

No. Equipment characteristics can change substantially with load and temperature.